iio: lps331ap: Fix wrong in_pressure_scale output value
Browse files Browse the repository at this point in the history
This patch fixes improper in_pressure_scale output that is
returned by the lps331ap barometer sensor driver. According
to the documentation the pressure after applying the scale has to
be expressed in kilopascal units. With erroneous implementation
the scale value larger by two orders of magnitude is returned -
2441410 instead of 24414.

Signed-off-by: Jacek Anaszewski <j.anaszewski@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Acked-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
  • Loading branch information
Jacek Anaszewski authored and Jonathan Cameron committed Jul 16, 2013
1 parent 8f6817a commit 67dbf54
Showing 1 changed file with 4 additions and 2 deletions.
6 changes: 4 additions & 2 deletions drivers/iio/pressure/st_pressure_core.c
Original file line number Diff line number Diff line change
Expand Up @@ -28,7 +28,9 @@
#include <linux/iio/common/st_sensors.h>
#include "st_pressure.h"

#define ST_PRESS_MBAR_TO_KPASCAL(x) (x * 10)
#define ST_PRESS_LSB_PER_MBAR 4096UL
#define ST_PRESS_KPASCAL_NANO_SCALE (100000000UL / \
ST_PRESS_LSB_PER_MBAR)
#define ST_PRESS_NUMBER_DATA_CHANNELS 1

/* DEFAULT VALUE FOR SENSORS */
Expand All @@ -51,8 +53,8 @@
#define ST_PRESS_1_FS_ADDR 0x23
#define ST_PRESS_1_FS_MASK 0x30
#define ST_PRESS_1_FS_AVL_1260_VAL 0x00
#define ST_PRESS_1_FS_AVL_1260_GAIN ST_PRESS_MBAR_TO_KPASCAL(244141)
#define ST_PRESS_1_FS_AVL_TEMP_GAIN 2083000
#define ST_PRESS_1_FS_AVL_1260_GAIN ST_PRESS_KPASCAL_NANO_SCALE