Skip to content

Commit

Permalink
iio: mxs-lradc: Fix temperature offset
Browse files Browse the repository at this point in the history
0° Kelvin is actually −273.15°C, not -272.15°C. Fix the temperature offset.
Also improve the comment explaining the calculation.

Reported-by: Janusz Użycki <j.uzycki@elpromaelectronics.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Acked-by: Stefan Wahren <stefan.wahren@i2se.com>
Acked-by: Marek Vasut <marex@denx.de>
Cc: <stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
  • Loading branch information
Alexandre Belloni authored and Jonathan Cameron committed Oct 11, 2015
1 parent eda7d0f commit b94e228
Showing 1 changed file with 5 additions and 4 deletions.
9 changes: 5 additions & 4 deletions drivers/staging/iio/adc/mxs-lradc.c
Original file line number Diff line number Diff line change
Expand Up @@ -915,11 +915,12 @@ static int mxs_lradc_read_raw(struct iio_dev *iio_dev,
case IIO_CHAN_INFO_OFFSET:
if (chan->type == IIO_TEMP) {
/* The calculated value from the ADC is in Kelvin, we
* want Celsius for hwmon so the offset is
* -272.15 * scale
* want Celsius for hwmon so the offset is -273.15
* The offset is applied before scaling so it is
* actually -213.15 * 4 / 1.012 = -1079.644268
*/
*val = -1075;
*val2 = 691699;
*val = -1079;
*val2 = 644268;

return IIO_VAL_INT_PLUS_MICRO;
}
Expand Down

0 comments on commit b94e228