Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Input: wacom - override 'pressure_max' with value from HID_USAGE_PRES…
…SURE The 0xEC sensor is used in multiple tablet PCs and curiously has versions that report 256 levels of pressure (Samsung Slate 7) as well as versions that report 1024 levels (Lenovo Thinkpad Yoga). To allow both versions to work properly, we allow the value of HID_USAGE_PRESSURE reported to override pressure_max. Signed-off-by: Jason Gerecke <killertofu@gmail.com> Tested-by: Aaron Skomra <Aaron.Skomra@wacom.com> Reviewed-by: Carl Worth <cworth@cworth.org> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
- Loading branch information