ALSA: oxygen: fix analog capture on Claro halo cards
Browse files Browse the repository at this point in the history
On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
  • Loading branch information
Erik J. Staab authored and Takashi Iwai committed Sep 22, 2010
1 parent b30a3f6 commit 0873a5a
Showing 1 changed file with 4 additions and 0 deletions.
4 changes: 4 additions & 0 deletions sound/pci/oxygen/oxygen.c
Original file line number Diff line number Diff line change
Expand Up @@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
chip->model.suspend = claro_suspend;
chip->model.resume = claro_resume;
chip->model.set_adc_params = set_ak5385_params;
chip->model.device_config = PLAYBACK_0_TO_I2S |
PLAYBACK_1_TO_SPDIF |
CAPTURE_0_FROM_I2S_2 |
CAPTURE_1_FROM_SPDIF;
break;
}
if (id->driver_data == MODEL_MERIDIAN ||