Skip to content

Commit

Permalink
regulator: palmas: configure enable time for LDOs
Browse files Browse the repository at this point in the history
As per datasheet (Referred TPS65913), the on-time for LDO is
500micro second. If LDO6 is in vibrator mode then the on-time
is 2000us.

Set the enable_time on regulator descriptor accordingly.

Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
  • Loading branch information
Laxman Dewangan authored and Mark Brown committed Sep 10, 2013
1 parent 0f45aa8 commit 087d30e
Showing 1 changed file with 6 additions and 0 deletions.
6 changes: 6 additions & 0 deletions drivers/regulator/palmas-regulator.c
Original file line number Diff line number Diff line change
Expand Up @@ -979,6 +979,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
pmic->desc[id].min_uV = 900000;
pmic->desc[id].uV_step = 50000;
pmic->desc[id].linear_min_sel = 1;
pmic->desc[id].enable_time = 500;
pmic->desc[id].vsel_reg =
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
palmas_regs_info[id].vsel_addr);
Expand All @@ -997,6 +998,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
pmic->desc[id].min_uV = 450000;
pmic->desc[id].uV_step = 25000;
}

/* LOD6 in vibrator mode will have enable time 2000us */
if (pdata && pdata->ldo6_vibrator &&
(id == PALMAS_REG_LDO6))
pmic->desc[id].enable_time = 2000;
} else {
pmic->desc[id].n_voltages = 1;
pmic->desc[id].ops = &palmas_ops_extreg;
Expand Down

0 comments on commit 087d30e