ab8500-charger: Add backup battery charge voltages on the ab8540
Browse files Browse the repository at this point in the history
Add 2.7v, 2.9v, 3.0v, 3.2v and 3.3v charging voltages for backup
battery. Before that only 2.5v, 2.6v, 2.8v, 3.1v were available.

Signed-off-by: Yang QU <yang.qu@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Maxime COQUELIN <maxime.coquelin@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Tested-by: Xiao Mei ZHANG <xiaomei.zhang@stericsson.com>
  • Loading branch information
Yang QU authored and Lee Jones committed Mar 7, 2013
1 parent e82c5bd commit 0f4aa40
Show file tree
Hide file tree
Showing 2 changed files with 37 additions and 6 deletions.
19 changes: 17 additions & 2 deletions drivers/power/ab8500_charger.c
Original file line number Diff line number Diff line change
Expand Up @@ -2836,6 +2836,7 @@ static int ab8500_charger_usb_get_property(struct power_supply *psy,
static int ab8500_charger_init_hw_registers(struct ab8500_charger *di)
{
int ret = 0;
u8 bup_vch_range = 0, vbup33_vrtcn = 0;

/* Setup maximum charger current and voltage for ABB cut2.0 */
if (!is_ab8500_1p1_or_earlier(di->parent)) {
Expand Down Expand Up @@ -2945,15 +2946,29 @@ static int ab8500_charger_init_hw_registers(struct ab8500_charger *di)
}

/* Backup battery voltage and current */
if (di->bm->bkup_bat_v > BUP_VCH_SEL_3P1V)
bup_vch_range = BUP_VCH_RANGE;
if (di->bm->bkup_bat_v == BUP_VCH_SEL_3P3V)
vbup33_vrtcn = VBUP33_VRTCN;

ret = abx500_set_register_interruptible(di->dev,
AB8500_RTC,
AB8500_RTC_BACKUP_CHG_REG,
di->bm->bkup_bat_v |
di->bm->bkup_bat_i);
(di->bm->bkup_bat_v & 0x3) | di->bm->bkup_bat_i);
if (ret) {
dev_err(di->dev, "failed to setup backup battery charging\n");
goto out;
}
if (is_ab8540(di->parent)) {
ret = abx500_set_register_interruptible(di->dev,
AB8500_RTC,
AB8500_RTC_CTRL1_REG,
bup_vch_range | vbup33_vrtcn);
if (ret) {
dev_err(di->dev, "failed to setup backup battery charging\n");
goto out;
}
}

/* Enable backup battery charging */
abx500_mask_and_set_register_interruptible(di->dev,
Expand Down
24 changes: 20 additions & 4 deletions include/linux/mfd/abx500/ab8500-bm.h
Original file line number Diff line number Diff line change
Expand Up @@ -105,6 +105,7 @@
#define AB8500_RTC_BACKUP_CHG_REG 0x0C
#define AB8500_RTC_CC_CONF_REG 0x01
#define AB8500_RTC_CTRL_REG 0x0B
#define AB8500_RTC_CTRL1_REG 0x11

/*
* OTP register offsets
Expand Down Expand Up @@ -179,10 +180,25 @@
#define BUP_ICH_SEL_300UA 0x08
#define BUP_ICH_SEL_700UA 0x0C

#define BUP_VCH_SEL_2P5V 0x00
#define BUP_VCH_SEL_2P6V 0x01
#define BUP_VCH_SEL_2P8V 0x02
#define BUP_VCH_SEL_3P1V 0x03
enum bup_vch_sel {
BUP_VCH_SEL_2P5V,
BUP_VCH_SEL_2P6V,
BUP_VCH_SEL_2P8V,
BUP_VCH_SEL_3P1V,
/*
* Note that the following 5 values 2.7v, 2.9v, 3.0v, 3.2v, 3.3v
* are only available on ab8540. You can't choose these 5
* voltage on ab8500/ab8505/ab9540.
*/
BUP_VCH_SEL_2P7V,
BUP_VCH_SEL_2P9V,
BUP_VCH_SEL_3P0V,
BUP_VCH_SEL_3P2V,
BUP_VCH_SEL_3P3V,
};

#define BUP_VCH_RANGE 0x02
#define VBUP33_VRTCN 0x01

/* Battery OVV constants */
#define BATT_OVV_ENA 0x02
Expand Down

0 comments on commit 0f4aa40