serial: samsung: wait for transfer completion before clock disable
Browse files Browse the repository at this point in the history
This patch adds waiting until transmit buffer and shifter will be empty
before clock disabling.

Without this fix it's possible to have clock disabled while data was
not transmited yet, which causes unproper state of TX line and problems
in following data transfers.

Cc: <stable@vger.kernel.org> # v2.6.26+
Signed-off-by: Robert Baldyga <r.baldyga@samsung.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
  • Loading branch information
Robert Baldyga authored and Greg Kroah-Hartman committed Nov 26, 2014
1 parent ddcbad9 commit 1ff383a
Showing 1 changed file with 4 additions and 0 deletions.
4 changes: 4 additions & 0 deletions drivers/tty/serial/samsung.c
Original file line number Diff line number Diff line change
Expand Up @@ -559,11 +559,15 @@ static void s3c24xx_serial_pm(struct uart_port *port, unsigned int level,
unsigned int old)
{
struct s3c24xx_uart_port *ourport = to_ourport(port);
int timeout = 10000;

ourport->pm_level = level;

switch (level) {
case 3:
while (--timeout && !s3c24xx_serial_txempty_nofifo(port))
udelay(100);

if (!IS_ERR(ourport->baudclk))
clk_disable_unprepare(ourport->baudclk);

Expand Down