ds2760_battery: handle full_active_uAh == 0 case correctly
Browse files Browse the repository at this point in the history
In systems where the battery monitor is not part of the battery pack and
is hence not bootstrapped with sane values, the full_active_uAh is
likely to be zero.

Handle that case by defaulting to the rated_capacity information which
can be passed to the driver using the new module parameter.

Signed-off-by: Daniel Mack <daniel@caiaq.de>
Cc: Szabolcs Gyurko <szabolcs.gyurko@tlt.hu>
Acked-by: Matt Reimer <mreimer@vpop.net>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
  • Loading branch information
Daniel Mack authored and Anton Vorontsov committed Jul 30, 2009
1 parent c1e7219 commit 25f2bfa
Showing 1 changed file with 7 additions and 2 deletions.
9 changes: 7 additions & 2 deletions drivers/power/ds2760_battery.c
Original file line number Diff line number Diff line change
Expand Up @@ -172,8 +172,13 @@ static int ds2760_battery_read_status(struct ds2760_device_info *di)
di->full_active_uAh = di->raw[DS2760_ACTIVE_FULL] << 8 |
di->raw[DS2760_ACTIVE_FULL + 1];

scale[0] = di->raw[DS2760_ACTIVE_FULL] << 8 |
di->raw[DS2760_ACTIVE_FULL + 1];
/* If the full_active_uAh value is not given, fall back to the rated
* capacity. This is likely to happen when chips are not part of the
* battery pack and is therefore not bootstrapped. */
if (di->full_active_uAh == 0)
di->full_active_uAh = di->rated_capacity / 1000L;

scale[0] = di->full_active_uAh;
for (i = 1; i < 5; i++)
scale[i] = scale[i - 1] + di->raw[DS2760_ACTIVE_FULL + 2 + i];