ACPICA: Fix allowable release order for ASL mutex objects
Browse files Browse the repository at this point in the history
The ACPI 4.0 specification has been changed to make the SyncLevel
for mutex objects more useful. When releasing a mutex, the
synclevel of the mutex must now be the same as the current sync
level. This makes more sense. This change updates the code to
match the spec.

Signed-off-by: Bob Moore <robert.moore@intel.com>
Signed-off-by: Lin Ming <ming.m.lin@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
  • Loading branch information
Bob Moore authored and Len Brown committed May 27, 2009
1 parent 10a3b46 commit 315c728
Showing 1 changed file with 11 additions and 4 deletions.
15 changes: 11 additions & 4 deletions drivers/acpi/acpica/exmutex.c
Original file line number Diff line number Diff line change
Expand Up @@ -402,10 +402,14 @@ acpi_ex_release_mutex(union acpi_operand_object *obj_desc,
}

/*
* The sync level of the mutex must be less than or equal to the current
* sync level
* The sync level of the mutex must be equal to the current sync level. In
* other words, the current level means that at least one mutex at that
* level is currently being held. Attempting to release a mutex of a
* different level can only mean that the mutex ordering rule is being
* violated. This behavior is clarified in ACPI 4.0 specification.
*/
if (obj_desc->mutex.sync_level > walk_state->thread->current_sync_level) {
if (obj_desc->mutex.sync_level !=
walk_state->thread->current_sync_level) {
ACPI_ERROR((AE_INFO,
"Cannot release Mutex [%4.4s], SyncLevel mismatch: mutex %d current %d",
acpi_ut_get_node_name(obj_desc->mutex.node),
Expand All @@ -423,10 +427,13 @@ acpi_ex_release_mutex(union acpi_operand_object *obj_desc,
walk_state->thread->acquired_mutex_list->mutex.original_sync_level;

status = acpi_ex_release_mutex_object(obj_desc);
if (ACPI_FAILURE(status)) {
return_ACPI_STATUS(status);
}

if (obj_desc->mutex.acquisition_depth == 0) {

/* Restore the original sync_level */
/* Restore the previous sync_level */

walk_state->thread->current_sync_level = previous_sync_level;
}
Expand Down