s3c_adc_battery: Average over more than one adc sample
Browse files Browse the repository at this point in the history
Some sources for adc battery information provide only inaccurate results
where the read value differs from the real value with positive and negative
offsets. For such sources it can be more accurate to collect two or more
value sample and use the average of all collected values.

This patch adds pdata options volt_samples, current_samples and
backup_volt_samples to specifiy the number of samples to collect,
reads the specified number of samples and calculates the average of those.
For unset sample-number-values a default of 1 is assumed.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
  • Loading branch information
Heiko Stübner authored and Anton Vorontsov committed Jan 6, 2012
1 parent ded7fc7 commit 34aed73
Show file tree
Hide file tree
Showing 2 changed files with 26 additions and 3 deletions.
25 changes: 22 additions & 3 deletions drivers/power/s3c_adc_battery.c
Original file line number Diff line number Diff line change
Expand Up @@ -47,6 +47,22 @@ static void s3c_adc_bat_ext_power_changed(struct power_supply *psy)
msecs_to_jiffies(JITTER_DELAY));
}

static int gather_samples(struct s3c_adc_client *client, int num, int channel)
{
int value, i;

/* default to 1 if nothing is set */
if (num < 1)
num = 1;

value = 0;
for (i = 0; i < num; i++)
value += s3c_adc_read(client, channel);
value /= num;

return value;
}

static enum power_supply_property s3c_adc_backup_bat_props[] = {
POWER_SUPPLY_PROP_VOLTAGE_NOW,
POWER_SUPPLY_PROP_VOLTAGE_MIN,
Expand All @@ -67,7 +83,8 @@ static int s3c_adc_backup_bat_get_property(struct power_supply *psy,
if (bat->volt_value < 0 ||
jiffies_to_msecs(jiffies - bat->timestamp) >
BAT_POLL_INTERVAL) {
bat->volt_value = s3c_adc_read(bat->client,
bat->volt_value = gather_samples(bat->client,
bat->pdata->backup_volt_samples,
bat->pdata->backup_volt_channel);
bat->volt_value *= bat->pdata->backup_volt_mult;
bat->timestamp = jiffies;
Expand Down Expand Up @@ -139,9 +156,11 @@ static int s3c_adc_bat_get_property(struct power_supply *psy,
if (bat->volt_value < 0 || bat->cur_value < 0 ||
jiffies_to_msecs(jiffies - bat->timestamp) >
BAT_POLL_INTERVAL) {
bat->volt_value = s3c_adc_read(bat->client,
bat->volt_value = gather_samples(bat->client,
bat->pdata->volt_samples,
bat->pdata->volt_channel) * bat->pdata->volt_mult;
bat->cur_value = s3c_adc_read(bat->client,
bat->cur_value = gather_samples(bat->client,
bat->pdata->current_samples,
bat->pdata->current_channel) * bat->pdata->current_mult;
bat->timestamp = jiffies;
}
Expand Down
4 changes: 4 additions & 0 deletions include/linux/s3c_adc_battery.h
Original file line number Diff line number Diff line change
Expand Up @@ -25,6 +25,10 @@ struct s3c_adc_bat_pdata {
const unsigned int current_channel;
const unsigned int backup_volt_channel;

const unsigned int volt_samples;
const unsigned int current_samples;
const unsigned int backup_volt_samples;

const unsigned int volt_mult;
const unsigned int current_mult;
const unsigned int backup_volt_mult;
Expand Down