[S390] dasd: correct sense byte condition for SIM
Browse files Browse the repository at this point in the history
SIM sense data are always 32 bit sense data so sense byte 27 bit 0
has not to be set.

Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
  • Loading branch information
Stefan Haberland authored and Martin Schwidefsky committed Dec 25, 2008
1 parent faf16aa commit 50afd20
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion drivers/s390/block/dasd_eckd.c
Original file line number Diff line number Diff line change
Expand Up @@ -1496,7 +1496,7 @@ static void dasd_eckd_handle_unsolicited_interrupt(struct dasd_device *device,


/* service information message SIM */
if (irb->esw.esw0.erw.cons && (irb->ecw[27] & DASD_SENSE_BIT_0) &&
if (irb->esw.esw0.erw.cons && !(irb->ecw[27] & DASD_SENSE_BIT_0) &&
((irb->ecw[6] & DASD_SIM_SENSE) == DASD_SIM_SENSE)) {
dasd_3990_erp_handle_sim(device, irb->ecw);
dasd_schedule_device_bh(device);