drm/radeon/kms: Fix logic error in DP HPD handler
Browse files Browse the repository at this point in the history
Only disable the pipe if the monitor is physically
disconnected.  The previous logic also disabled the
pipe if the link was trained.

Fixes:
https://bugs.freedesktop.org/show_bug.cgi?id=41248

Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Cc: stable@kernel.org
Signed-off-by: Dave Airlie <airlied@redhat.com>
  • Loading branch information
Alex Deucher authored and Dave Airlie committed Oct 3, 2011
1 parent 6375bda commit 5ba7ddf
Showing 1 changed file with 4 additions and 4 deletions.
8 changes: 4 additions & 4 deletions drivers/gpu/drm/radeon/radeon_connectors.c
Original file line number Diff line number Diff line change
Expand Up @@ -68,11 +68,11 @@ void radeon_connector_hotplug(struct drm_connector *connector)
if (connector->connector_type == DRM_MODE_CONNECTOR_DisplayPort) {
int saved_dpms = connector->dpms;

if (radeon_hpd_sense(rdev, radeon_connector->hpd.hpd) &&
radeon_dp_needs_link_train(radeon_connector))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_ON);
else
/* Only turn off the display it it's physically disconnected */
if (!radeon_hpd_sense(rdev, radeon_connector->hpd.hpd))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_OFF);
else if (radeon_dp_needs_link_train(radeon_connector))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_ON);
connector->dpms = saved_dpms;
}
}
Expand Down