net/mlx4_en: Set correct port parameters during device initialization
Browse files Browse the repository at this point in the history
Set valid port parameters: MTU and flow control configuration when
configuring the port during HW device initialization,
prior to the net device open() being called.
Using  invalid parameters (such as all zeros)
could lead to bad firmware behavior.

Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il>
Signed-off-by: David S. Miller <davem@davemloft.net>
  • Loading branch information
Yevgeny Petrilin authored and David S. Miller committed Jun 25, 2012
1 parent 6de0298 commit 5c8e904
Showing 1 changed file with 4 additions and 2 deletions.
6 changes: 4 additions & 2 deletions drivers/net/ethernet/mellanox/mlx4/en_netdev.c
Original file line number Diff line number Diff line change
Expand Up @@ -1204,9 +1204,11 @@ int mlx4_en_init_netdev(struct mlx4_en_dev *mdev, int port,
en_warn(priv, "Using %d RX rings\n", prof->rx_ring_num);

/* Configure port */
mlx4_en_calc_rx_buf(dev);
err = mlx4_SET_PORT_general(mdev->dev, priv->port,
MLX4_EN_MIN_MTU,
0, 0, 0, 0);
priv->rx_skb_size + ETH_FCS_LEN,
prof->tx_pause, prof->tx_ppp,
prof->rx_pause, prof->rx_ppp);
if (err) {
en_err(priv, "Failed setting port general configurations "
"for port %d, with error %d\n", priv->port, err);
Expand Down