ab8500-fg: Allow capacity to raise from 1% when charging
Browse files Browse the repository at this point in the history
When battery capacity was going below 1% fg is not supposed
to report 0% unless we've got the LOW_BAT IRQ, no matter
what the FG-algorithm says. This made fg get stuck at 1% if
charger is connected when capacity is 1%.

Signed-off-by: Hakan BERG <hakan.berg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Srinidhi KASAGAR <srinidhi.kasagar@stericsson.com>
  • Loading branch information
Hakan Berg authored and Lee Jones committed Mar 7, 2013
1 parent 908fe8d commit 6427761
Showing 1 changed file with 2 additions and 4 deletions.
6 changes: 2 additions & 4 deletions drivers/power/ab8500_fg.c
Original file line number Diff line number Diff line change
Expand Up @@ -1354,9 +1354,6 @@ static void ab8500_fg_check_capacity_limits(struct ab8500_fg *di, bool init)
* algorithm says.
*/
di->bat_cap.prev_percent = 1;
di->bat_cap.permille = 1;
di->bat_cap.prev_mah = 1;
di->bat_cap.mah = 1;
percent = 1;

changed = true;
Expand Down Expand Up @@ -1768,9 +1765,10 @@ static void ab8500_fg_algorithm(struct ab8500_fg *di)
ab8500_fg_algorithm_discharging(di);
}

dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d "
dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d %d "
"%d %d %d %d %d %d %d\n",
di->bat_cap.max_mah_design,
di->bat_cap.max_mah,
di->bat_cap.mah,
di->bat_cap.permille,
di->bat_cap.level,
Expand Down

0 comments on commit 6427761