brcmsmac: change lcnphy receive i/q calibration routine
The gain level control for the test tone has been changed. This calbration test tone is used to determine the i/q compensation. The i/q calibration routine has been reworked to accomodate this. Cc: Jonas Gorski <jogo@openwrt.org> Tested-by: David Herrmann <dh.herrmann@gmail.com> Reviewed-by: Pieter-Paul Giesberts <pieterpg@broadcom.com> Reviewed-by: Hante Meuleman <meuleman@broadcom.com> Signed-off-by: Arend van Spriel <arend@broadcom.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>