[PATCH] cciss: set default raid level when reading geometry fails
Browse files Browse the repository at this point in the history
This patch sets a default raid level on a volume that either does not support
reading the geometry or reports an invalid geometry for whatever reason. We
were always setting some values for heads and sectors but never set a raid
level. This caused lots of problems on some buggy firmware. Please consider
this for inclusion.

Thanks,
mikem

Signed-off-by: Mike Miller <mike.miller@hp.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
  • Loading branch information
Mike Miller authored and Jens Axboe committed Dec 18, 2006
1 parent e25db64 commit 89f97ad
Showing 1 changed file with 1 addition and 0 deletions.
1 change: 1 addition & 0 deletions drivers/block/cciss.c
Original file line number Diff line number Diff line change
Expand Up @@ -1907,6 +1907,7 @@ static void cciss_geometry_inquiry(int ctlr, int logvol,
"does not support reading geometry\n");
drv->heads = 255;
drv->sectors = 32; // Sectors per track
drv->raid_level = RAID_UNKNOWN;
} else {
drv->heads = inq_buff->data_byte[6];
drv->sectors = inq_buff->data_byte[7];