Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
leds: flash: document sysfs interface
Add a documentation of LED Flash class specific sysfs attributes. Signed-off-by: Jacek Anaszewski <j.anaszewski@samsung.com> Acked-by: Kyungmin Park <kyungmin.park@samsung.com> Cc: Richard Purdie <rpurdie@rpsys.net> Signed-off-by: Bryan Wu <cooloney@gmail.com>
- Loading branch information
Jacek Anaszewski
authored and
Bryan Wu
committed
Mar 10, 2015
1 parent
94fdec7
commit 9c4a8e1
Showing
1 changed file
with
80 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,80 @@ | ||
What: /sys/class/leds/<led>/flash_brightness | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read/write | ||
Set the brightness of this LED in the flash strobe mode, in | ||
microamperes. The file is created only for the flash LED devices | ||
that support setting flash brightness. | ||
|
||
The value is between 0 and | ||
/sys/class/leds/<led>/max_flash_brightness. | ||
|
||
What: /sys/class/leds/<led>/max_flash_brightness | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read only | ||
Maximum brightness level for this LED in the flash strobe mode, | ||
in microamperes. | ||
|
||
What: /sys/class/leds/<led>/flash_timeout | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read/write | ||
Hardware timeout for flash, in microseconds. The flash strobe | ||
is stopped after this period of time has passed from the start | ||
of the strobe. The file is created only for the flash LED | ||
devices that support setting flash timeout. | ||
|
||
What: /sys/class/leds/<led>/max_flash_timeout | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read only | ||
Maximum flash timeout for this LED, in microseconds. | ||
|
||
What: /sys/class/leds/<led>/flash_strobe | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read/write | ||
Flash strobe state. When written with 1 it triggers flash strobe | ||
and when written with 0 it turns the flash off. | ||
|
||
On read 1 means that flash is currently strobing and 0 means | ||
that flash is off. | ||
|
||
What: /sys/class/leds/<led>/flash_fault | ||
Date: March 2015 | ||
KernelVersion: 4.0 | ||
Contact: Jacek Anaszewski <j.anaszewski@samsung.com> | ||
Description: read only | ||
Space separated list of flash faults that may have occurred. | ||
Flash faults are re-read after strobing the flash. Possible | ||
flash faults: | ||
|
||
* led-over-voltage - flash controller voltage to the flash LED | ||
has exceeded the limit specific to the flash controller | ||
* flash-timeout-exceeded - the flash strobe was still on when | ||
the timeout set by the user has expired; not all flash | ||
controllers may set this in all such conditions | ||
* controller-over-temperature - the flash controller has | ||
overheated | ||
* controller-short-circuit - the short circuit protection | ||
of the flash controller has been triggered | ||
* led-power-supply-over-current - current in the LED power | ||
supply has exceeded the limit specific to the flash | ||
controller | ||
* indicator-led-fault - the flash controller has detected | ||
a short or open circuit condition on the indicator LED | ||
* led-under-voltage - flash controller voltage to the flash | ||
LED has been below the minimum limit specific to | ||
the flash | ||
* controller-under-voltage - the input voltage of the flash | ||
controller is below the limit under which strobing the | ||
flash at full current will not be possible; | ||
the condition persists until this flag is no longer set | ||
* led-over-temperature - the temperature of the LED has exceeded | ||
its allowed upper limit |