Skip to content

Commit

Permalink
power_supply: cleanup of the OLPC battery driver
Browse files Browse the repository at this point in the history
Move portions of the massive switch statement into functions.  The layout of
this thing has already caused one bug (a break in the wrong place), it needed
to shrink.

Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
  • Loading branch information
Andres Salomon authored and Anton Vorontsov committed May 4, 2008
1 parent d7eb9e3 commit b2bd8a3
Showing 1 changed file with 118 additions and 73 deletions.
191 changes: 118 additions & 73 deletions drivers/power/olpc_battery.c
Original file line number Diff line number Diff line change
Expand Up @@ -86,6 +86,117 @@ static struct power_supply olpc_ac = {

static char bat_serial[17]; /* Ick */

static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
{
if (olpc_platform_info.ecver > 0x44) {
if (ec_byte & BAT_STAT_CHARGING)
val->intval = POWER_SUPPLY_STATUS_CHARGING;
else if (ec_byte & BAT_STAT_DISCHARGING)
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* er,... */
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
} else {
/* Older EC didn't report charge/discharge bits */
if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* Not _necessarily_ true but EC doesn't tell all yet */
val->intval = POWER_SUPPLY_STATUS_CHARGING;
}

return 0;
}

static int olpc_bat_get_health(union power_supply_propval *val)
{
uint8_t ec_byte;
int ret;

ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
if (ret)
return ret;

switch (ec_byte) {
case 0:
val->intval = POWER_SUPPLY_HEALTH_GOOD;
break;

case BAT_ERR_OVERTEMP:
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
break;

case BAT_ERR_OVERVOLTAGE:
val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
break;

case BAT_ERR_INFOFAIL:
case BAT_ERR_OUT_OF_CONTROL:
case BAT_ERR_ID_FAIL:
case BAT_ERR_ACR_FAIL:
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
break;

default:
/* Eep. We don't know this failure code */
ret = -EIO;
}

return ret;
}

static int olpc_bat_get_mfr(union power_supply_propval *val)
{
uint8_t ec_byte;
int ret;

ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
if (ret)
return ret;

switch (ec_byte >> 4) {
case 1:
val->strval = "Gold Peak";
break;
case 2:
val->strval = "BYD";
break;
default:
val->strval = "Unknown";
break;
}

return ret;
}

static int olpc_bat_get_tech(union power_supply_propval *val)
{
uint8_t ec_byte;
int ret;

ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
if (ret)
return ret;

switch (ec_byte & 0xf) {
case 1:
val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
break;
case 2:
val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
break;
default:
val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
break;
}

return ret;
}

/*********************************************************************
* Battery properties
*********************************************************************/
Expand Down Expand Up @@ -113,25 +224,10 @@ static int olpc_bat_get_property(struct power_supply *psy,

switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
if (olpc_platform_info.ecver > 0x44) {
if (ec_byte & BAT_STAT_CHARGING)
val->intval = POWER_SUPPLY_STATUS_CHARGING;
else if (ec_byte & BAT_STAT_DISCHARGING)
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* er,... */
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
} else {
/* Older EC didn't report charge/discharge bits */
if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* Not _necessarily_ true but EC doesn't tell all yet */
val->intval = POWER_SUPPLY_STATUS_CHARGING;
break;
}
ret = olpc_bat_get_status(val, ec_byte);
if (ret)
return ret;
break;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
break;
Expand All @@ -140,72 +236,21 @@ static int olpc_bat_get_property(struct power_supply *psy,
if (ec_byte & BAT_STAT_DESTROY)
val->intval = POWER_SUPPLY_HEALTH_DEAD;
else {
ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
ret = olpc_bat_get_health(val);
if (ret)
return ret;

switch (ec_byte) {
case 0:
val->intval = POWER_SUPPLY_HEALTH_GOOD;
break;

case BAT_ERR_OVERTEMP:
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
break;

case BAT_ERR_OVERVOLTAGE:
val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
break;

case BAT_ERR_INFOFAIL:
case BAT_ERR_OUT_OF_CONTROL:
case BAT_ERR_ID_FAIL:
case BAT_ERR_ACR_FAIL:
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
break;

default:
/* Eep. We don't know this failure code */
return -EIO;
}
}
break;

case POWER_SUPPLY_PROP_MANUFACTURER:
ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
ret = olpc_bat_get_mfr(val);
if (ret)
return ret;

switch (ec_byte >> 4) {
case 1:
val->strval = "Gold Peak";
break;
case 2:
val->strval = "BYD";
break;
default:
val->strval = "Unknown";
break;
}
break;
case POWER_SUPPLY_PROP_TECHNOLOGY:
ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
ret = olpc_bat_get_tech(val);
if (ret)
return ret;

switch (ec_byte & 0xf) {
case 1:
val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
break;
case 2:
val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
break;
default:
val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
break;
}
break;
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);
Expand Down

0 comments on commit b2bd8a3

Please sign in to comment.