[PATCH] x86_64: Explain why HPET T0_CMP register is written twice
Browse files Browse the repository at this point in the history
After writing the CFG register, the first value written to the T0_CMP
register is the value at which next interrupt should be triggered, every
value after that sets the period of the interrupt. For that reason, the code
needs to write the value twice - to set both the phase and period.

[AK: I had already figured it out by myself, but it's still useful
to have a comment for this.]

Signed-off-by: Vojtech Pavlik <vojtech@suse.cz>
Signed-off-by: Andi Kleen <ak@suse.de>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
  • Loading branch information
Vojtech Pavlik authored and Linus Torvalds committed Jun 26, 2006
1 parent 4221133 commit b2df3dd
Showing 1 changed file with 2 additions and 2 deletions.
4 changes: 2 additions & 2 deletions arch/x86_64/kernel/time.c
Original file line number Diff line number Diff line change
Expand Up @@ -795,8 +795,8 @@ static int hpet_timer_stop_set_go(unsigned long tick)
if (hpet_use_timer) {
hpet_writel(HPET_TN_ENABLE | HPET_TN_PERIODIC | HPET_TN_SETVAL |
HPET_TN_32BIT, HPET_T0_CFG);
hpet_writel(hpet_tick, HPET_T0_CMP);
hpet_writel(hpet_tick, HPET_T0_CMP); /* AK: why twice? */
hpet_writel(hpet_tick, HPET_T0_CMP); /* next interrupt */
hpet_writel(hpet_tick, HPET_T0_CMP); /* period */
cfg |= HPET_CFG_LEGACY;
}
/*
Expand Down