hwmon: (adt7473) Fix voltage conversion routines
Fix voltage conversion routines. Based on an earlier patch from Paulius Zaleckas. According to the datasheet voltage is scaled with resistors and value 192 is nominal voltage. 0 is 0V. Signed-off-by: Jean Delvare <khali@linux-fr.org> Cc: Paulius Zaleckas <paulius.zaleckas@teltonika.lt> Cc: Darrick J. Wong <djwong@us.ibm.com>