regulator: lp3972: Convert to get_voltage_sel
regulator_list_voltage_table() returns -EINVAL if selector >= n_voltages. Thus we don't need to check if reg is greater than LP3972_BUCK_VOL_MAX_IDX in lp3972_[ldo|dcdc]_get_voltage_sel. LP3972_BUCK_VOL_MIN_IDX and LP3972_BUCK_VOL_MAX_IDX are not used, remove them. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>