drm/panel: simple: Correct minimum hsync length of the HannStar HSD07…
Browse files Browse the repository at this point in the history
…0PWW1 panel

According to the data sheet, the minimum horizontal blanking interval
is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
minimum working horizontal blanking interval to be 60 clocks.

Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
Signed-off-by: Lucas Stach <l.stach@pengutronix.de>
Signed-off-by: Thierry Reding <treding@nvidia.com>
  • Loading branch information
Philipp Zabel authored and Thierry Reding committed Aug 14, 2015
1 parent 58d6a7b commit d901d2b
Showing 1 changed file with 6 additions and 1 deletion.
7 changes: 6 additions & 1 deletion drivers/gpu/drm/panel/panel-simple.c
Original file line number Diff line number Diff line change
Expand Up @@ -713,7 +713,12 @@ static const struct display_timing hannstar_hsd070pww1_timing = {
.hactive = { 1280, 1280, 1280 },
.hfront_porch = { 1, 1, 10 },
.hback_porch = { 1, 1, 10 },
.hsync_len = { 52, 158, 661 },
/*
* According to the data sheet, the minimum horizontal blanking interval
* is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
* minimum working horizontal blanking interval to be 60 clocks.
*/
.hsync_len = { 58, 158, 661 },
.vactive = { 800, 800, 800 },
.vfront_porch = { 1, 1, 10 },
.vback_porch = { 1, 1, 10 },
Expand Down