Skip to content

Commit

Permalink
ab8500_fg: Don't clear the CCMuxOffset bit
Browse files Browse the repository at this point in the history
The CCMuxOffset bit is not kept set. This will force the
columb counter of the AB8500 to use the measure offset
calibration. This should increase the accuracy of the fuel
gauge.

Signed-off-by: Kalle Komierowski <karl.komierowski@stericsson.com>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
  • Loading branch information
Kalle Komierowski authored and Lee Jones committed Dec 11, 2012
1 parent f8e96df commit e32ad07
Showing 1 changed file with 4 additions and 4 deletions.
8 changes: 4 additions & 4 deletions drivers/power/ab8500_fg.c
Original file line number Diff line number Diff line change
Expand Up @@ -484,8 +484,9 @@ static int ab8500_fg_coulomb_counter(struct ab8500_fg *di, bool enable)
di->flags.fg_enabled = true;
} else {
/* Clear any pending read requests */
ret = abx500_set_register_interruptible(di->dev,
AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG, 0);
ret = abx500_mask_and_set_register_interruptible(di->dev,
AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG,
(RESET_ACCU | READ_REQ), 0);
if (ret)
goto cc_err;

Expand Down Expand Up @@ -1403,8 +1404,7 @@ static void ab8500_fg_algorithm_discharging(struct ab8500_fg *di)
sleep_time = di->bat->fg_params->init_timer;

/* Discard the first [x] seconds */
if (di->init_cnt >
di->bat->fg_params->init_discard_time) {
if (di->init_cnt > di->bat->fg_params->init_discard_time) {
ab8500_fg_calc_cap_discharge_voltage(di, true);

ab8500_fg_check_capacity_limits(di, true);
Expand Down

0 comments on commit e32ad07