SNI RM200 don't have the i8042 controller connected to the EISA bus, but have a second address range for onboard devices. This patch handles the two possible address ranges for the i8042 on SNI RMs. Signed-off-by: Thomas Bogendoerfer <tsbogend@alpha.franken.de> Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
- Loading branch information
Thomas Bogendoerfer
authored and
Dmitry Torokhov
committed
Mar 14, 2008
1 parent
2a2dcd6
commit f178244
Showing
2 changed files
with
77 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,75 @@ | ||
#ifndef _I8042_SNIRM_H | ||
#define _I8042_SNIRM_H | ||
|
||
#include <asm/sni.h> | ||
|
||
/* | ||
* This program is free software; you can redistribute it and/or modify it | ||
* under the terms of the GNU General Public License version 2 as published by | ||
* the Free Software Foundation. | ||
*/ | ||
|
||
/* | ||
* Names. | ||
*/ | ||
|
||
#define I8042_KBD_PHYS_DESC "onboard/serio0" | ||
#define I8042_AUX_PHYS_DESC "onboard/serio1" | ||
#define I8042_MUX_PHYS_DESC "onboard/serio%d" | ||
|
||
/* | ||
* IRQs. | ||
*/ | ||
static int i8042_kbd_irq; | ||
static int i8042_aux_irq; | ||
#define I8042_KBD_IRQ i8042_kbd_irq | ||
#define I8042_AUX_IRQ i8042_aux_irq | ||
|
||
static void __iomem *kbd_iobase; | ||
|
||
#define I8042_COMMAND_REG (kbd_iobase + 0x64UL) | ||
#define I8042_DATA_REG (kbd_iobase + 0x60UL) | ||
|
||
static inline int i8042_read_data(void) | ||
{ | ||
return readb(kbd_iobase + 0x60UL); | ||
} | ||
|
||
static inline int i8042_read_status(void) | ||
{ | ||
return readb(kbd_iobase + 0x64UL); | ||
} | ||
|
||
static inline void i8042_write_data(int val) | ||
{ | ||
writeb(val, kbd_iobase + 0x60UL); | ||
} | ||
|
||
static inline void i8042_write_command(int val) | ||
{ | ||
writeb(val, kbd_iobase + 0x64UL); | ||
} | ||
static inline int i8042_platform_init(void) | ||
{ | ||
/* RM200 is strange ... */ | ||
if (sni_brd_type == SNI_BRD_RM200) { | ||
kbd_iobase = ioremap(0x16000000, 4); | ||
i8042_kbd_irq = 33; | ||
i8042_aux_irq = 44; | ||
} else { | ||
kbd_iobase = ioremap(0x14000000, 4); | ||
i8042_kbd_irq = 1; | ||
i8042_aux_irq = 12; | ||
} | ||
if (!kbd_iobase) | ||
return -ENOMEM; | ||
|
||
return 0; | ||
} | ||
|
||
static inline void i8042_platform_exit(void) | ||
{ | ||
|
||
} | ||
|
||
#endif /* _I8042_SNIRM_H */ |