Bluetooth: Fix Class of Device indication when powering off
Browse files Browse the repository at this point in the history
When a HCI device is powered off the Management interface specification
dictates that the class of device value is indicated as zero. This patch
fixes sending of the appropriate class of device changed event when a
HCI device is powered off.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Acked-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Gustavo Padovan <gustavo.padovan@collabora.co.uk>
  • Loading branch information
Johan Hedberg authored and Gustavo Padovan committed Jan 23, 2013
1 parent 46818ed commit fe03888
Showing 1 changed file with 6 additions and 0 deletions.
6 changes: 6 additions & 0 deletions net/bluetooth/mgmt.c
Original file line number Diff line number Diff line change
Expand Up @@ -2987,7 +2987,13 @@ int mgmt_powered(struct hci_dev *hdev, u8 powered)
}
} else {
u8 status = MGMT_STATUS_NOT_POWERED;
u8 zero_cod[] = { 0, 0, 0 };

mgmt_pending_foreach(0, hdev, cmd_status_rsp, &status);

if (memcmp(hdev->dev_class, zero_cod, sizeof(zero_cod)) != 0)
mgmt_event(MGMT_EV_CLASS_OF_DEV_CHANGED, hdev,
zero_cod, sizeof(zero_cod), NULL);
}

err = new_settings(hdev, match.sk);
Expand Down