serial: mcf: fix no driver name in probe output
Browse files Browse the repository at this point in the history
The current output of the device probing looks like this:

ColdFire internal UART serial driver
(NULL device *): ttyS0 at MMIO 0xfc060000 (irq = 90, base_baud = 5208333) is a ColdFire UART
console [ttyS0] enabled
(NULL device *): ttyS1 at MMIO 0xfc064000 (irq = 91, base_baud = 5208333) is a ColdFire UART
(NULL device *): ttyS2 at MMIO 0xfc068000 (irq = 92, base_baud = 5208333) is a ColdFire UART

Fix the port device linkage at probing time so that the device name is
printed out properly, and not "(NULL device *)".

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
  • Loading branch information
Greg Ungerer authored and Greg Kroah-Hartman committed Jan 9, 2015
1 parent ebffbc6 commit 201d897
Showing 1 changed file with 1 addition and 0 deletions.
1 change: 1 addition & 0 deletions drivers/tty/serial/mcf.c
Original file line number Diff line number Diff line change
Expand Up @@ -629,6 +629,7 @@ static int mcf_probe(struct platform_device *pdev)
port->mapbase = platp[i].mapbase;
port->membase = (platp[i].membase) ? platp[i].membase :
(unsigned char __iomem *) platp[i].mapbase;
port->dev = &pdev->dev;
port->iotype = SERIAL_IO_MEM;
port->irq = platp[i].irq;
port->uartclk = MCF_BUSCLK;
Expand Down