i2c-bfin-twi: abort transfer is MEM bit is reset unexpectedly
Browse files Browse the repository at this point in the history
Sometimes, the first I2C transmit interrupt is not serviced in time (like
when higher priority interrupts take too long).  Since the RESTART bit is
not set before the next I2C clock, when the TWI handler is finally called,
the I2C session is aborted (MEM bit is reset) and both SMITSERV and MCOMP
int status bits are set.

So when this happens, abort the transfer.

Reported-by: Isabelle Leonardi <i.leonardi@detracom.fr>
Signed-off-by: Sonic Zhang <sonic.zhang@analog.com>
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
  • Loading branch information
Sonic Zhang authored and Ben Dooks committed Jun 27, 2011
1 parent af4087e commit 4a65163
Showing 1 changed file with 7 additions and 1 deletion.
8 changes: 7 additions & 1 deletion drivers/i2c/busses/i2c-bfin-twi.c
Original file line number Diff line number Diff line change
Expand Up @@ -193,7 +193,13 @@ static void bfin_twi_handle_interrupt(struct bfin_twi_iface *iface,
return;
}
if (twi_int_status & MCOMP) {
if (iface->cur_mode == TWI_I2C_MODE_COMBINED) {
if ((read_MASTER_CTL(iface) & MEN) == 0 &&
(iface->cur_mode == TWI_I2C_MODE_REPEAT ||
iface->cur_mode == TWI_I2C_MODE_COMBINED)) {
iface->result = -1;
write_INT_MASK(iface, 0);
write_MASTER_CTL(iface, 0);
} else if (iface->cur_mode == TWI_I2C_MODE_COMBINED) {
if (iface->readNum == 0) {
/* set the read number to 1 and ask for manual
* stop in block combine mode
Expand Down