iio: adc: ad7124: Disable all channels at probe time
Browse files Browse the repository at this point in the history
When during a measurement two channels are enabled, two measurements are
done that are reported sequencially in the DATA register. As the code
triggered by reading one of the sysfs properties expects that only one
channel is enabled it only reads the first data set which might or might
not belong to the intended channel.

To prevent this situation disable all channels during probe. This fixes
a problem in practise because the reset default for channel 0 is
enabled. So all measurements before the first measurement on channel 0
(which disables channel 0 at the end) might report wrong values.

Fixes: 7b8d045 ("iio: adc: ad7124: allow more than 8 channels")
Reviewed-by: Nuno Sa <nuno.sa@analog.com>
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/20241104101905.845737-2-u.kleine-koenig@baylibre.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
  • Loading branch information
Uwe Kleine-König authored and Jonathan Cameron committed Dec 7, 2024
1 parent 4636e85 commit 4be339a
Showing 1 changed file with 3 additions and 0 deletions.
3 changes: 3 additions & 0 deletions drivers/iio/adc/ad7124.c
Original file line number Diff line number Diff line change
Expand Up @@ -917,6 +917,9 @@ static int ad7124_setup(struct ad7124_state *st)
* set all channels to this default value.
*/
ad7124_set_channel_odr(st, i, 10);

/* Disable all channels to prevent unintended conversions. */
ad_sd_write_reg(&st->sd, AD7124_CHANNEL(i), 2, 0);
}

ret = ad_sd_write_reg(&st->sd, AD7124_ADC_CONTROL, 2, st->adc_control);
Expand Down