Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
mmc: sdhci: Fix data command CRC error handling
Existing data command CRC error handling is non-standard and does not work with some Intel host controllers. Specifically, the assumption that the host controller will continue operating normally after the error interrupt, is not valid. Change the driver to handle the error in the same manner as a data CRC error, taking care to ensure that the data line reset is done for single or multi-block transfers, and it is done before unmapping DMA. Signed-off-by: Adrian Hunter <adrian.hunter@intel.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
- Loading branch information
Adrian Hunter
authored and
Ulf Hansson
committed
Dec 17, 2018
1 parent
7e2d23e
commit 4bf7809
Showing
1 changed file
with
15 additions
and
25 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters