regulator: core: don't return error with inadequate reason
Browse files Browse the repository at this point in the history
drms_uA_update() always returns failure when it cannot find regulator's
input voltage.  But if hardware supports load configuration with
ops->set_load() and the input regulator isn't specified with valid reason
such as the input regulator is battery, not finding input voltage is
normal so such case should not return with an error.

Avoid such inadequate error return by checking input/output voltages
only when drms_uA_update() is about to configure load with enum based
ops->set_mode().

Cc: Liam Girdwood <lgirdwood@gmail.com>
Cc: Mark Brown <broonie@kernel.org>
Cc: Bjorn Andersson <bjorn.andersson@linaro.org>
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Joonwoo Park <joonwoop@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
  • Loading branch information
Joonwoo Park authored and Mark Brown committed Sep 24, 2016
1 parent 29b4817 commit 5777661
Showing 1 changed file with 18 additions and 18 deletions.
36 changes: 18 additions & 18 deletions drivers/regulator/core.c
Original file line number Diff line number Diff line change
Expand Up @@ -679,24 +679,6 @@ static int drms_uA_update(struct regulator_dev *rdev)
!rdev->desc->ops->set_load)
return -EINVAL;

/* get output voltage */
output_uV = _regulator_get_voltage(rdev);
if (output_uV <= 0) {
rdev_err(rdev, "invalid output voltage found\n");
return -EINVAL;
}

/* get input voltage */
input_uV = 0;
if (rdev->supply)
input_uV = regulator_get_voltage(rdev->supply);
if (input_uV <= 0)
input_uV = rdev->constraints->input_uV;
if (input_uV <= 0) {
rdev_err(rdev, "invalid input voltage found\n");
return -EINVAL;
}

/* calc total requested load */
list_for_each_entry(sibling, &rdev->consumer_list, list)
current_uA += sibling->uA_load;
Expand All @@ -709,6 +691,24 @@ static int drms_uA_update(struct regulator_dev *rdev)
if (err < 0)
rdev_err(rdev, "failed to set load %d\n", current_uA);
} else {
/* get output voltage */
output_uV = _regulator_get_voltage(rdev);
if (output_uV <= 0) {
rdev_err(rdev, "invalid output voltage found\n");
return -EINVAL;
}

/* get input voltage */
input_uV = 0;
if (rdev->supply)
input_uV = regulator_get_voltage(rdev->supply);
if (input_uV <= 0)
input_uV = rdev->constraints->input_uV;
if (input_uV <= 0) {
rdev_err(rdev, "invalid input voltage found\n");
return -EINVAL;
}

/* now get the optimum mode for our new total regulator load */
mode = rdev->desc->ops->get_optimum_mode(rdev, input_uV,
output_uV, current_uA);
Expand Down