mlx4_core: Workaround firmware bug in query dev cap
Browse files Browse the repository at this point in the history
ConnectX firmware is supposed to report the number blue flame
registers per page as log2 of the value.  However, due to a firmware
bug, it reports actual number.  This patch works around this by
checking if the number of registers calculated fits within a page.  If
it does not, we use 8 registers per page.

Signed-off-by: Eli Cohen <eli@mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
  • Loading branch information
Eli Cohen authored and Roland Dreier committed Dec 2, 2010
1 parent e27535b commit 58d74bb
Showing 1 changed file with 4 additions and 0 deletions.
4 changes: 4 additions & 0 deletions drivers/net/mlx4/fw.c
Original file line number Diff line number Diff line change
Expand Up @@ -289,6 +289,10 @@ int mlx4_QUERY_DEV_CAP(struct mlx4_dev *dev, struct mlx4_dev_cap *dev_cap)
MLX4_GET(field, outbox, QUERY_DEV_CAP_LOG_BF_REG_SZ_OFFSET);
dev_cap->bf_reg_size = 1 << (field & 0x1f);
MLX4_GET(field, outbox, QUERY_DEV_CAP_LOG_MAX_BF_REGS_PER_PAGE_OFFSET);
if ((1 << (field & 0x3f)) > (PAGE_SIZE / dev_cap->bf_reg_size)) {
mlx4_warn(dev, "firmware bug: log2 # of blue flame regs is invalid (%d), forcing 3\n", field & 0x1f);
field = 3;
}
dev_cap->bf_regs_per_page = 1 << (field & 0x3f);
mlx4_dbg(dev, "BlueFlame available (reg size %d, regs/page %d)\n",
dev_cap->bf_reg_size, dev_cap->bf_regs_per_page);