Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
iio: imu: bmi270: fix initial sampling frequency configuration
In the bmi270_configure_imu() function, the accelerometer and gyroscope configuration registers are incorrectly written with the mask BMI270_PWR_CONF_ADV_PWR_SAVE_MSK, which is unrelated to these registers. As a result, the accelerometer's sampling frequency is set to 200 Hz instead of the intended 100 Hz. Remove the mask to ensure the correct bits are set in the configuration registers. Fixes: 3ea5154 ("iio: imu: Add i2c driver for bmi270 imu") Signed-off-by: Gustavo Silva <gustavograzs@gmail.com> Reviewed-by: Alex Lanzano <lanzano.alex@gmail.com> Link: https://patch.msgid.link/20250304-bmi270-odr-fix-v1-1-384dbcd699fb@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
- Loading branch information