clocksource: sunxi: Stop timer from ticking before enabling interrupts
Browse files Browse the repository at this point in the history
The sun4i timer can still be ticking when we enable the interrupt.
If another timer is actually used (A7 architected timer, for example),
odds are that the interrupt will eventually fire with the event_handler
pointer being NULL.

The obvious fix it to stop the timer before registering the interrupt.

Observed and tested on sun7i (cubietruck).

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
  • Loading branch information
Marc Zyngier authored and Daniel Lezcano committed Dec 10, 2013
1 parent 4c4b053 commit 6db50bb
Showing 1 changed file with 3 additions and 0 deletions.
3 changes: 3 additions & 0 deletions drivers/clocksource/sun4i_timer.c
Original file line number Diff line number Diff line change
Expand Up @@ -179,6 +179,9 @@ static void __init sun4i_timer_init(struct device_node *node)
writel(TIMER_CTL_CLK_SRC(TIMER_CTL_CLK_SRC_OSC24M),
timer_base + TIMER_CTL_REG(0));

/* Make sure timer is stopped before playing with interrupts */
sun4i_clkevt_time_stop(0);

ret = setup_irq(irq, &sun4i_timer_irq);
if (ret)
pr_warn("failed to setup irq %d\n", irq);