Skip to content

Commit

Permalink
ARM: dts: sun8i-h3: Add thermal trip points/cooling maps
Browse files Browse the repository at this point in the history
This enables passive cooling by down-regulating CPU voltage
and frequency.

For trip points, I used a slightly lowered values from the BSP
code. The critical temperature of 110°C from BSP code seemed
like a lot, so I rounded it off to 100°C.

The critical trip point value is 30°C above the maximum recommended
ambient temperature (70°C) for the SoC from the datasheet, so there's
some headroom even at such a high ambient temperature.

Signed-off-by: Ondrej Jirman <megous@megous.com>
Signed-off-by: Maxime Ripard <maxime@cerno.tech>
  • Loading branch information
Ondrej Jirman authored and Maxime Ripard committed Feb 25, 2020
1 parent 4c7eeb9 commit 7ad9f3d
Showing 1 changed file with 25 additions and 0 deletions.
25 changes: 25 additions & 0 deletions arch/arm/boot/dts/sun8i-h3.dtsi
Original file line number Diff line number Diff line change
Expand Up @@ -41,6 +41,7 @@
*/

#include "sunxi-h3-h5.dtsi"
#include <dt-bindings/thermal/thermal.h>

/ {
cpu0_opp_table: opp_table0 {
Expand Down Expand Up @@ -227,6 +228,30 @@
polling-delay-passive = <0>;
polling-delay = <0>;
thermal-sensors = <&ths 0>;

trips {
cpu_hot_trip: cpu-hot {
temperature = <80000>;
hysteresis = <2000>;
type = "passive";
};

cpu_very_hot_trip: cpu-very-hot {
temperature = <100000>;
hysteresis = <0>;
type = "critical";
};
};

cooling-maps {
cpu-hot-limit {
trip = <&cpu_hot_trip>;
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
};
};
Expand Down

0 comments on commit 7ad9f3d