regulator: max8997: Use uV in voltage_map_desc
Current code does integer division (min_vol = min_uV / 1000) before pass min_vol to max8997_get_voltage_proper_val(). So it is possible min_vol is truncated to a smaller value. For example, if the request min_uV is 800900 for ldo. min_vol = 800900 / 1000 = 800 (mV) Then max8997_get_voltage_proper_val returns 800 mV for this case which is lower than the requested voltage. Use uV rather than mV in voltage_map_desc to prevent truncation by integer division. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: stable@vger.kernel.org