drm/i915: fix PCH PLL assertion check for 3 pipes
Browse files Browse the repository at this point in the history
Add a couple of checks now that we're using the 3rd transcoder:
  1) make sure the transcoder PLL enable bit is set for the transcoder
     in question
  2) when checking actual PLL enable, use the selected PLL number rather
     than the transcoder number (they could be different now)

Signed-off-by: Jesse Barnes <jbarnes@virtuousgeek.org>
Tested-By: Eugeni Dodonov <eugeni.dodonov@intel.com>
Reviewed-By: Eugeni Dodonov <eugeni.dodonov@intel.com>
Signed-off-by: Keith Packard <keithp@keithp.com>
  • Loading branch information
Jesse Barnes authored and Keith Packard committed Oct 20, 2011
1 parent 7577056 commit d3ccbe8
Showing 1 changed file with 13 additions and 0 deletions.
13 changes: 13 additions & 0 deletions drivers/gpu/drm/i915/intel_display.c
Original file line number Diff line number Diff line change
Expand Up @@ -803,6 +803,19 @@ static void assert_pch_pll(struct drm_i915_private *dev_priv,
u32 val;
bool cur_state;

if (HAS_PCH_CPT(dev_priv->dev)) {
u32 pch_dpll;

pch_dpll = I915_READ(PCH_DPLL_SEL);

/* Make sure the selected PLL is enabled to the transcoder */
WARN(!((pch_dpll >> (4 * pipe)) & 8),
"transcoder %d PLL not enabled\n", pipe);

/* Convert the transcoder pipe number to a pll pipe number */
pipe = (pch_dpll >> (4 * pipe)) & 1;
}

reg = PCH_DPLL(pipe);
val = I915_READ(reg);
cur_state = !!(val & DPLL_VCO_ENABLE);
Expand Down

0 comments on commit d3ccbe8

Please sign in to comment.