be2net: Bug fix to avoid soft lockup in loopback test.
Browse files Browse the repository at this point in the history
This change ensures that loopback test command gives up after 4 seconds when
the hardware is not responsive. This could happen if the ports are connected
properly in loopback mode.

Signed-off-by: Sarveshwar Bandi <sarveshwarb@serverengines.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
  • Loading branch information
Sarveshwar Bandi authored and David S. Miller committed Dec 24, 2009
1 parent 1242b6f commit d7b9014
Showing 1 changed file with 1 addition and 0 deletions.
1 change: 1 addition & 0 deletions drivers/net/benet/be_cmds.c
Original file line number Diff line number Diff line change
Expand Up @@ -1501,6 +1501,7 @@ int be_cmd_loopback_test(struct be_adapter *adapter, u32 port_num,

be_cmd_hdr_prepare(&req->hdr, CMD_SUBSYSTEM_LOWLEVEL,
OPCODE_LOWLEVEL_LOOPBACK_TEST, sizeof(*req));
req->hdr.timeout = 4;

req->pattern = cpu_to_le64(pattern);
req->src_port = cpu_to_le32(port_num);
Expand Down