drivers/rtc/rtc-pl031.c: fix the missing operation on enable
Browse files Browse the repository at this point in the history
The RTC control register should be enabled in the process of
initializing.

Without this patch, I failed to enable RTC in Hisilicon Hi3620 SoC.  The
register mapping section in RTC is always read as zero.  So I doubt that
ST guys may already enable this register in bootloader.  So they won't
meet this issue.

Signed-off-by: Haojian Zhuang <haojian.zhuang@linaro.org>
Cc: Srinidhi Kasagar <srinidhi.kasagar@stericsson.com>
Cc: Linus Walleij <linus.walleij@linaro.org>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: <stable@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
  • Loading branch information
Haojian Zhuang authored and Linus Torvalds committed Feb 5, 2013
1 parent 72fca4a commit e7e034e
Showing 1 changed file with 5 additions and 3 deletions.
8 changes: 5 additions & 3 deletions drivers/rtc/rtc-pl031.c
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,7 @@
#define RTC_YMR 0x34 /* Year match register */
#define RTC_YLR 0x38 /* Year data load register */

#define RTC_CR_EN (1 << 0) /* counter enable bit */
#define RTC_CR_CWEN (1 << 26) /* Clockwatch enable bit */

#define RTC_TCR_EN (1 << 1) /* Periodic timer enable bit */
Expand Down Expand Up @@ -320,7 +321,7 @@ static int pl031_probe(struct amba_device *adev, const struct amba_id *id)
struct pl031_local *ldata;
struct pl031_vendor_data *vendor = id->data;
struct rtc_class_ops *ops = &vendor->ops;
unsigned long time;
unsigned long time, data;

ret = amba_request_regions(adev, NULL);
if (ret)
Expand All @@ -345,10 +346,11 @@ static int pl031_probe(struct amba_device *adev, const struct amba_id *id)
dev_dbg(&adev->dev, "designer ID = 0x%02x\n", amba_manf(adev));
dev_dbg(&adev->dev, "revision = 0x%01x\n", amba_rev(adev));

data = readl(ldata->base + RTC_CR);
/* Enable the clockwatch on ST Variants */
if (vendor->clockwatch)
writel(readl(ldata->base + RTC_CR) | RTC_CR_CWEN,
ldata->base + RTC_CR);
data |= RTC_CR_CWEN;
writel(data | RTC_CR_EN, ldata->base + RTC_CR);

/*
* On ST PL031 variants, the RTC reset value does not provide correct
Expand Down