net/mlx5: E-switch, Fix printing wrong error value
Browse files Browse the repository at this point in the history
When mlx5_modify_header_alloc() fails, instead of printing the error
value returned, current error log prints 0.

Fix by printing correct error value returned by
mlx5_modify_header_alloc().

Fixes: 6724e66 ("net/mlx5: E-Switch, Get reg_c1 value on miss")
Signed-off-by: Parav Pandit <parav@mellanox.com>
Reviewed-by: Roi Dayan <roid@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
  • Loading branch information
Parav Pandit authored and Saeed Mahameed committed Apr 30, 2020
1 parent 7994998 commit e986453
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c
Original file line number Diff line number Diff line change
Expand Up @@ -1550,9 +1550,9 @@ static int esw_create_restore_table(struct mlx5_eswitch *esw)
MLX5_FLOW_NAMESPACE_KERNEL, 1,
modact);
if (IS_ERR(mod_hdr)) {
err = PTR_ERR(mod_hdr);
esw_warn(dev, "Failed to create restore mod header, err: %d\n",
err);
err = PTR_ERR(mod_hdr);
goto err_mod_hdr;
}