net: ipa: fix HOLB timer calculation
For IPA v4.2, the exact interpretation of the register that defines the timeout for avoiding head-of-line blocking was a little unclear. We're only assigning a 0 timeout to it right now, so that wasn't very important. But now that I know how it's supposed to work, I'm fixing it. The register represents a tick counter, where each tick is equal to 128 IPA core clock cycles. For IPA v3.5.1, the register contains a simple counter value. But for IPA v4.2, the register contains two fields, base and scale, which approximate the tick counter as: ticks = base << scale The base and scale values to use for a given tick count are computed using clever bit operations, and measures are taken to make the resulting time period as close as possible to that requested. There's no need for ipa_endpoint_init_hol_block_timer() to return an error, so change its return type to void. Signed-off-by: Alex Elder <elder@linaro.org> Signed-off-by: David S. Miller <davem@davemloft.net>