net: phy: adin: implement cable-test support
The ADIN1300/ADIN1200 support cable diagnostics using TDR. The cable fault detection is automatically run on all four pairs looking at all combinations of pair faults by first putting the PHY in standby (clear the LINK_EN bit, PHY_CTRL_3 register, Address 0x0017) and then enabling the diagnostic clock (set the DIAG_CLK_EN bit, PHY_CTRL_1 register, Address 0x0012). Cable diagnostics can then be run (set the CDIAG_RUN bit in the CDIAG_RUN register, Address 0xBA1B). The results are reported for each pair in the cable diagnostics results registers, CDIAG_DTLD_RSLTS_0, CDIAG_DTLD_RSLTS_1, CDIAG_DTLD_RSLTS_2, and CDIAG_DTLD_RSLTS_3, Address 0xBA1D to Address 0xBA20). The distance to the first fault for each pair is reported in the cable fault distance registers, CDIAG_FLT_DIST_0, CDIAG_FLT_DIST_1, CDIAG_FLT_DIST_2, and CDIAG_FLT_DIST_3, Address 0xBA21 to Address 0xBA24). This change implements support for this using phylib's cable-test support. Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Link: https://lore.kernel.org/r/20201103074436.93790-2-alexandru.ardelean@analog.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
- Loading branch information
Alexandru Ardelean
authored and
Jakub Kicinski
committed
Nov 5, 2020
1 parent
85ba75b
commit f2531d4
Showing
1 changed file
with
138 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters