mlxsw: pci: Derive event type from event queue number
Browse files Browse the repository at this point in the history
Due to a hardware issue in Spectrum-2, the field event_type of the event
queue element (EQE) has become reserved. It was used to distinguish between
command interface completion events and completion events.

Use queue number to determine event type, as command interface completion
events are always received on EQ0 and mlxsw driver maps completion events
to EQ1.

Fixes: c3ab435 ("mlxsw: spectrum: Extend to support Spectrum-2 ASIC")
Signed-off-by: Nir Dotan <nird@mellanox.com>
Reviewed-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
  • Loading branch information
Nir Dotan authored and David S. Miller committed Oct 4, 2018
1 parent cec4de3 commit f3c84a8
Showing 1 changed file with 7 additions and 4 deletions.
11 changes: 7 additions & 4 deletions drivers/net/ethernet/mellanox/mlxsw/pci.c
Original file line number Diff line number Diff line change
Expand Up @@ -718,14 +718,17 @@ static void mlxsw_pci_eq_tasklet(unsigned long data)
memset(&active_cqns, 0, sizeof(active_cqns));

while ((eqe = mlxsw_pci_eq_sw_eqe_get(q))) {
u8 event_type = mlxsw_pci_eqe_event_type_get(eqe);

switch (event_type) {
case MLXSW_PCI_EQE_EVENT_TYPE_CMD:
/* Command interface completion events are always received on
* queue MLXSW_PCI_EQ_ASYNC_NUM (EQ0) and completion events
* are mapped to queue MLXSW_PCI_EQ_COMP_NUM (EQ1).
*/
switch (q->num) {
case MLXSW_PCI_EQ_ASYNC_NUM:
mlxsw_pci_eq_cmd_event(mlxsw_pci, eqe);
q->u.eq.ev_cmd_count++;
break;
case MLXSW_PCI_EQE_EVENT_TYPE_COMP:
case MLXSW_PCI_EQ_COMP_NUM:
cqn = mlxsw_pci_eqe_cqn_get(eqe);
set_bit(cqn, active_cqns);
cq_handle = true;
Expand Down