Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
iio: adc: vf610: use ADC clock within specification
Depending on conversion mode used, the ADC clock (ADCK) needs to be below a maximum frequency. According to Vybrid's data sheet this is 20MHz for the low power conversion mode. The ADC clock is depending on input clock, which is the bus clock by default. Vybrid SoC are typically clocked at at 400MHz or 500MHz, which leads to 66MHz or 83MHz bus clock respectively. Hence, a divider of 8 is required to stay below the specified maximum clock of 20MHz. Due to the different bus clock speeds, the resulting sampling frequency is not static. Hence use the ADC clock and calculate the actual available sampling frequency dynamically. This fixes bogous values observed on some 500MHz clocked Vybrid SoC. The resulting value usually showed Bit 9 being stuck at 1, or 0, which lead to a value of +/-512. Signed-off-by: Stefan Agner <stefan@agner.ch> Acked-by: Fugang Duan <B38611@freescale.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
- Loading branch information
Stefan Agner
authored and
Jonathan Cameron
committed
Mar 28, 2015
1 parent
bbc45f3
commit f54e9f2
Showing
1 changed file
with
61 additions
and
30 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters