thermal: core: Rewrite comments in handle_thermal_trip()
Browse files Browse the repository at this point in the history
Make the comments regarding trip crossing and threshold updates in
handle_thermal_trip() slightly more clear.

No functional impact.

Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
  • Loading branch information
Rafael J. Wysocki committed Apr 8, 2024
1 parent b1ae92d commit f99c1b8
Showing 1 changed file with 13 additions and 13 deletions.
26 changes: 13 additions & 13 deletions drivers/thermal/thermal_core.c
Original file line number Diff line number Diff line change
Expand Up @@ -368,18 +368,23 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
if (trip->temperature == THERMAL_TEMP_INVALID)
return;

/*
* If the trip temperature or hysteresis has been updated recently,
* the threshold needs to be computed again using the new values.
* However, its initial value still reflects the old ones and that
* is what needs to be compared with the previous zone temperature
* to decide which action to take.
*/
if (tz->last_temperature == THERMAL_TEMP_INVALID) {
/* Initialization. */
td->threshold = trip->temperature;
if (tz->temperature >= td->threshold)
td->threshold -= trip->hysteresis;
} else if (tz->last_temperature < td->threshold) {
/*
* The trip threshold is equal to the trip temperature, unless
* the latter has changed in the meantime. In either case,
* the trip is crossed if the current zone temperature is at
* least equal to its temperature, but otherwise ensure that
* the threshold and the trip temperature will be equal.
* There is no mitigation under way, so it needs to be started
* if the zone temperature exceeds the trip one. The new
* threshold is then set to the low temperature of the trip.
*/
if (tz->temperature >= trip->temperature) {
thermal_notify_tz_trip_up(tz, trip);
Expand All @@ -390,14 +395,9 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
}
} else {
/*
* The previous zone temperature was above or equal to the trip
* threshold, which would be equal to the "low temperature" of
* the trip (its temperature minus its hysteresis), unless the
* trip temperature or hysteresis had changed. In either case,
* the trip is crossed if the current zone temperature is below
* the low temperature of the trip, but otherwise ensure that
* the trip threshold will be equal to the low temperature of
* the trip.
* Mitigation is under way, so it needs to stop if the zone
* temperature falls below the low temperature of the trip.
* In that case, the trip temperature becomes the new threshold.
*/
if (tz->temperature < trip->temperature - trip->hysteresis) {
thermal_notify_tz_trip_down(tz, trip);
Expand Down