r8169: fix issue with confused RX unit after PHY power-down on RTL8411b
On RTL8411b the RX unit gets confused if the PHY is powered-down. This was reported in [0] and confirmed by Realtek. Realtek provided a sequence to fix the RX unit after PHY wakeup. The issue itself seems to have been there longer, the Fixes tag refers to where the fix applies properly. [0] https://bugzilla.redhat.com/show_bug.cgi?id=1692075 Fixes: a99790b ("r8169: Reinstate ASPM Support") Tested-by: Ionut Radu <ionut.radu@gmail.com> Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>