ACPICA: Fix SyncLevel support interaction with method auto-serialization
Browse files Browse the repository at this point in the history
ACPICA commit 253e3c03efc1a495d2aa61eee09ab1d0842a3dce

The control method auto-serialization can interfere with existing
ASL code that makes use of Mutex/Method SyncLevel support. This
change makes the auto-serialization transparent to the SyncLevel
support and management. David Box.

Link: https://github.com/acpica/acpica/commit/253e3c03
Signed-off-by: David E. Box <david.e.box@linux.intel.com>
Signed-off-by: Bob Moore <robert.moore@intel.com>
Signed-off-by: Lv Zheng <lv.zheng@intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
  • Loading branch information
David E. Box authored and Rafael J. Wysocki committed Jan 1, 2016
1 parent 0e166e4 commit 33d3a2a
Showing 1 changed file with 13 additions and 2 deletions.
15 changes: 13 additions & 2 deletions drivers/acpi/acpica/dsmethod.c
Original file line number Diff line number Diff line change
Expand Up @@ -411,8 +411,19 @@ acpi_ds_begin_method_execution(struct acpi_namespace_node *method_node,

obj_desc->method.mutex->mutex.thread_id =
walk_state->thread->thread_id;
walk_state->thread->current_sync_level =
obj_desc->method.sync_level;

/*
* Update the current sync_level only if this is not an auto-
* serialized method. In the auto case, we have to ignore
* the sync level for the method mutex (created for the
* auto-serialization) because we have no idea of what the
* sync level should be. Therefore, just ignore it.
*/
if (!(obj_desc->method.info_flags &
ACPI_METHOD_IGNORE_SYNC_LEVEL)) {
walk_state->thread->current_sync_level =
obj_desc->method.sync_level;
}
} else {
obj_desc->method.mutex->mutex.
original_sync_level =
Expand Down