Skip to content

Commit

Permalink
regulator: palmas: Remove wrong comment for the equation calculating …
Browse files Browse the repository at this point in the history
…num_voltages

Current equation on the comment is wrong.
For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1.
Since the linear mapping for PALMAS is not all starting from 0, the equation
on the comment is not useful and misleading. Thus remove it.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
  • Loading branch information
Axel Lin authored and Mark Brown committed Sep 16, 2013
1 parent 087d30e commit ae3e101
Showing 1 changed file with 0 additions and 6 deletions.
6 changes: 0 additions & 6 deletions drivers/regulator/palmas-regulator.c
Original file line number Diff line number Diff line change
Expand Up @@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
#define SMPS_CTRL_MODE_ECO 0x02
#define SMPS_CTRL_MODE_PWM 0x03

/* These values are derived from the data sheet. And are the number of steps
* where there is a voltage change, the ranges at beginning and end of register
* max/min values where there are no change are ommitted.
*
* So they are basically (maxV-minV)/stepV
*/
#define PALMAS_SMPS_NUM_VOLTAGES 122
#define PALMAS_SMPS10_NUM_VOLTAGES 2
#define PALMAS_LDO_NUM_VOLTAGES 50
Expand Down