Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
iio: accel: adxl367: fix setting odr for activity time update
Fix setting the odr value to update activity time based on frequency derrived by recent odr, and not by obsolete odr value. The [small] bug: When _adxl367_set_odr() is called with a new odr value, it first writes the new odr value to the hardware register ADXL367_REG_FILTER_CTL. Second, it calls _adxl367_set_act_time_ms(), which calls adxl367_time_ms_to_samples(). Here st->odr still holds the old odr value. This st->odr member is used to derrive a frequency value, which is applied to update ADXL367_REG_TIME_ACT. Hence, the idea is to update activity time, based on possibilities and power consumption by the current ODR rate. Finally, when the function calls return, again in _adxl367_set_odr() the new ODR is assigned to st->odr. The fix: When setting a new ODR value is set to ADXL367_REG_FILTER_CTL, also ADXL367_REG_TIME_ACT should probably be updated with a frequency based on the recent ODR value and not the old one. Changing the location of the assignment to st->odr fixes this. Fixes: cbab791 ("iio: accel: add ADXL367 driver") Signed-off-by: Lothar Rubusch <l.rubusch@gmail.com> Reviewed-by: Marcelo Schmitt <marcelo.schmitt1@gmail.com> Link: https://patch.msgid.link/20250309193515.2974-1-l.rubusch@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
- Loading branch information